Single Ply
TPO Roofing
Carries an average solar reflective index of 72
Single Ply Types
- TPO
- PVC
- KEE
- EPDM
TPO Roofing Attachment Methods
- Mechanical Attachment
- Fully adhered.
- Induction Welding
Pros of using TPO Roofing
- One of the most Cost-effective Commercial Roofing systems currently available on the market
- Carries an average solar reflective index of 72, meaning this system reflects UV rays which in essence keeps the surface of the roof cool which makes the R Value of your roofing system more efficient which creates cost savings on electricity.
- Most recommended and efficient for large warehouses and or Cold storage spaces
- The warranty does not require substrate slope in order to achieve a premium 20-year NDL warranty.
- Puncture Resistance warranty Add On’s for upgrading to Fleece back Membrane – meaning the system will be covered from any punctures from the servicing of any roof top equipment.
- Average chemical resistance exposure
- As long a the system is maintained properly by a Certified applicator throughout the course of its life this system can last 20-40 years
Cons of using TPO Roofing
- Not ideal for a roof’s with too many penetrations and equipment
- Not ideal for high foot traffic roofs
- Not ideal for Buildings 200’+ in elevation
- Not Ideal for buildings with Cooling Towers as the chemicals are much more abrasive and can cause premature failures.
- Slippery when wet
- For dead level systems Algae will grow in areas of water ponding
Warranty Availability
- TPO Roofing – 10, 15-, 20-, 25-, and 30-year Warranties currently available for this system (25-30 year require upgrade in membrane thickness)
- No Dollar Limit Warranty, Workmanship Warranties, Material and Labor Warranties available
Approved direct substrate applications
- Concrete
- Gypsum
- Gypsum Coverboards
- polyisocyanurate insulation
- Modified Inter-ply membranes
TPO Membrane can be Fully adhered directly to the substrates noted above
- EPS
- polyisocyanurate insulation
- Gypsum Coverboards
- Class A Fire barrier
- Over approved existing roofing substrates
TPO Membrane can be Mechanically attached and or Induction welding to the substrates noted above
Single Ply
TPO Roofing
Carries an average solar reflective index of 72
Single Ply Types
- TPO
- PVC
- KEE
- EPDM
TPO Roofing Attachment Methods
- Mechanical Attachment
- Fully adhered.
- Induction Welding
Pros of using TPO Roofing
- One of the most Cost-effective Commercial Roofing systems currently available on the market
- Carries an average solar reflective index of 72, meaning this system reflects UV rays which in essence keeps the surface of the roof cool which makes the R Value of your roofing system more efficient which creates cost savings on electricity.
- Most recommended and efficient for large warehouses and or Cold storage spaces
- The warranty does not require substrate slope in order to achieve a premium 20-year NDL warranty.
- Puncture Resistance warranty Add On’s for upgrading to Fleece back Membrane – meaning the system will be covered from any punctures from the servicing of any roof top equipment.
- Average chemical resistance exposure
- As long a the system is maintained properly by a Certified applicator throughout the course of its life this system can last 20-40 years
Cons of using TPO Roofing
- Not ideal for a roof’s with too many penetrations and equipment
- Not ideal for high foot traffic roofs
- Not ideal for Buildings 200’+ in elevation
- Not Ideal for buildings with Cooling Towers as the chemicals are much more abrasive and can cause premature failures.
- Slippery when wet
- For dead level systems Algae will grow in areas of water ponding
Warranty Availability
- TPO Roofing – 10, 15-, 20-, 25-, and 30-year Warranties currently available for this system (25-30 year require upgrade in membrane thickness)
- No Dollar Limit Warranty, Workmanship Warranties, Material and Labor Warranties available
Approved direct substrate applications
- Concrete
- Gypsum
- Gypsum Coverboards
- polyisocyanurate insulation
- Modified Inter-ply membranes
TPO Membrane can be Fully adhered directly to the substrates noted above
EPS
- polyisocyanurate insulation
- Gypsum Coverboards
- Class A Fire barrier
- Over approved existing roofing substrates
TPO Membrane can be Mechanically attached and or Induction welding to the substrates noted above
Single Ply - TPO Roofing
More Specifications
TPO Roofing Colors
- Bright White is the standard color available.
- All other standard colors available with min orders of 50,000 SF
- White and grey are the only colors that carry an SRI Value of 72+
TPO Durability & Wind Resistance
- TPO Roofing is a Durable roofing system for roofs with minimal traffic and average penetrations, Walk Pad is recommended around all serviceable roof top units.
- TPO carries 55 MPH wind exclusions and is eligible for Wind riders of up to 125 MPH.
Manufacturer Brochure Hyper-Links
- https://www.carlislesyntec.com/document-viewer/sure-weld-tpo-roofing-systems-brochure/IAq6V6I5Q06oIxh9rJRYyA
- https://documents.gaf.com/brochures-&-literature/brochure__everguard_tpo_comeg120.pdf
- https://www.jm.com/content/dam/jm/global/en/commercial-roofing/brochures/RS-7301%20Final%20General%20Roofing%20Catalog.pdf


Single Ply
PVC Roofing
Carries an average solar reflective index of 72
Single Ply Types
- TPO
- PVC
- KEE
- EPDM
PVC Roofing Attachment Methods
- Mechanical Attachment
- Fully adhered.
- Induction Welding
Pros of using PVC Roofing
- Carries an average solar reflective index of 72, meaning this system reflects UV rays which in essence keeps the surface of the roof cool which makes the R Value of your roofing system more efficient which creates cost savings on electricity.
- Most recommended and efficient for large warehouses, Cold storage spaces, Airports, Food processing facilities
- The warranty does not require substrate slope in order to achieve a premium 20-year NDL warranty.
- Puncture Resistance warranty Add On’s for upgrading to Fleece back Membrane – meaning the system will be covered from any punctures from the servicing of any roof top equipment.
- High Tolerance to chemical exposure
- As long a the system is maintained properly by a Certified applicator throughout the course of its life this system can last 20-40 years
Cons of using PVC Roofing
- Not ideal for a roof’s with too many penetrations and equipment
- Not ideal for high foot traffic roofs
- Not ideal for Buildings 200’+ in elevation
- Slippery when wet
- For dead level systems Algae will grow in areas of water ponding
Warranty Availability
- PVC Roofing – 10, 15-, 20-, 25-, and 30-year Warranties currently available for this system (25-30 year require upgrade in membrane thickness)
- No Dollar Limit Warranty, Workmanship Warranties, Material and Labor Warranties available
Approved direct substrate applications
- Concrete
- Gypsum
- Gypsum Coverboards
- polyisocyanurate insulation
- Modified Inter-ply membranes only
PVC Membrane can be Fully adhered directly to the substrates noted above (All structural substrates acceptable)
- EPS
- polyisocyanurate insulation
- Gypsum Coverboards
- Class A Fire barrier
- Over approved existing roofing substrates
PVC Membrane can be Mechanically attached and or Induction welding to the substrates noted above(Building structure Must be Steel, and or wood for this option)
Single Ply
PVC Roofing
Carries an average solar reflective index of 72
Single Ply Types
- TPO
- PVC
- KEE
- EPDM
PVC Roofing Attachment Methods
- Mechanical Attachment
- Fully adhered.
- Induction Welding
Pros of using PVC Roofing
- Carries an average solar reflective index of 72, meaning this system reflects UV rays which in essence keeps the surface of the roof cool which makes the R Value of your roofing system more efficient which creates cost savings on electricity.
- Most recommended and efficient for large warehouses, Cold storage spaces, Airports, Food processing facilities
- The warranty does not require substrate slope in order to achieve a premium 20-year NDL warranty.
- Puncture Resistance warranty Add On’s for upgrading to Fleece back Membrane – meaning the system will be covered from any punctures from the servicing of any roof top equipment.
- High Tolerance to chemical exposure
- As long a the system is maintained properly by a Certified applicator throughout the course of its life this system can last 20-40 years
Cons of using PVC Roofing
- Not ideal for a roof’s with too many penetrations and equipment
- Not ideal for high foot traffic roofs
- Not ideal for Buildings 200’+ in elevation
- Slippery when wet
- For dead level systems Algae will grow in areas of water ponding
Warranty Availability
- PVC Roofing – 10, 15-, 20-, 25-, and 30-year Warranties currently available for this system (25-30 year require upgrade in membrane thickness)
- No Dollar Limit Warranty, Workmanship Warranties, Material and Labor Warranties available
Approved direct substrate applications
- Concrete
- Gypsum
- Gypsum Coverboards
- polyisocyanurate insulation
- Modified Inter-ply membranes only
PVC Membrane can be Fully adhered directly to the substrates noted above (All structural substrates acceptable)
- EPS
- polyisocyanurate insulation
- Gypsum Coverboards
- Class A Fire barrier
- Over approved existing roofing substrates
PVC Membrane can be Mechanically attached and or Induction welding to the substrates noted above(Building structure Must be Steel, and or wood for this option)
Sly Ply - PVC Roofing
More Specifications
PVC Roofing Colors
- Bright White is the standard color available.
- All other standard colors available with min orders of 50,000 SF
- White and grey are the only colors that carry an SRI Value of 72+
PVC Durability & Wind Resistance
- PVC Roofing is a Durable roofing system for roofs with minimal traffic and average penetrations, Walk Pad is recommended around all serviceable roof top units.
- PVC carries 55 MPH wind exclusions and is eligible for Wind riders of up to 125 MPH.
Manufacturer Brochure Hyper-Links
- https://usa.sika.com/content/dam/dms/us01/m/sarnafil-roofing-systems.pdf
- https://www.carlislesyntec.com/en/Document-Viewer/sure-flex-pvc-brochure/gka7aZVc8EK4HlAESfKmIg
- https://soprema.us/wp-content/uploads/2020/08/220_SENTINEL-PVC-Brochure.pdf
- https://documents.gaf.com/brochures-&-literature/brochure__everguard_pvc_roofing_systems_comeg136.pdf?_gl=1*1fb4r6f*_ga*NTE0MjQxNzk5LjE3MTAxOTkzMzU.*_ga_NZXTQY46ZN*MTcxMDI4NDQ3NS4yLjEuMTcxMDI4NDU3NC4zMS4wLjA.
- https://www.jm.com/content/dam/jm/global/en/commercial-roofing/brochures/RS-7301%20Final%20General%20Roofing%20Catalog.pdf

Single Ply
KEE Roofing
Carries an average solar reflective index of 72
Single Ply Types
- TPO
- PVC
- KEE
- EPDM
KEE Roofing Attachment Methods
- Mechanical Attachment
- Fully adhered.
- Induction Welding
Pros of using KEE Roofing
- Carries an average solar reflective index of 72, meaning this system reflects UV rays which in essence keeps the surface of the roof cool which makes the R Value of your roofing system more efficient which creates cost savings on electricity.
- Most recommended and efficient for large warehouses, Cold storage spaces, Airports, Food processing facilities
- The warranty does not require substrate slope in order to achieve a premium 20-year NDL warranty.
- Puncture Resistance warranty Add On’s for upgrading to Fleece back Membrane – meaning the system will be covered from any punctures from the servicing of any roof top equipment.
- Extreme High Tolerance to chemical exposure
- Maintains its thickness for a lifetime.
- Available in Extreme Tough Membrane
- As long a the system is maintained properly by a Certified applicator throughout the course of its life this system can last 50 + years
Cons of using KEE Roofing
- Not ideal for high foot traffic roofs
- Not ideal for Buildings 200’+ in elevation
- Slippery when wet
- For dead level systems Algae will grow in areas of water ponding
Warranty Availability
- KEE Roofing – 10, 15-, 20-, 25-, and 30-year Warranties currently available for this system (25-30 year require upgrade in membrane thickness)
- No Dollar Limit Warranty, Workmanship Warranties, Material and Labor Warranties available
Approved direct substrate applications
- Concrete
- Gypsum
- Gypsum Coverboards
- polyisocyanurate insulation
- Modified Inter-ply membranes only.
KEE Membrane can be Fully adhered directly to the substrates noted above (All structural substrates acceptable)
- EPS
- polyisocyanurate insulation
- Gypsum Coverboards
- Class A Fire barrier
- Over approved existing roofing substrates
KEE Membrane can be Mechanically attached and or Induction welding to the substrates noted above(Building structure Must be Steel, and or wood for this option)
Single Ply
KEE Roofing
Carries an average solar reflective index of 72
Single Ply Types
- TPO
- PVC
- KEE
- EPDM
KEE Roofing Attachment Methods
- Mechanical Attachment
- Fully adhered.
- Induction Welding
Pros of using KEE Roofing
- Carries an average solar reflective index of 72, meaning this system reflects UV rays which in essence keeps the surface of the roof cool which makes the R Value of your roofing system more efficient which creates cost savings on electricity.
- Most recommended and efficient for large warehouses, Cold storage spaces, Airports, Food processing facilities
- The warranty does not require substrate slope in order to achieve a premium 20-year NDL warranty.
- Puncture Resistance warranty Add On’s for upgrading to Fleece back Membrane – meaning the system will be covered from any punctures from the servicing of any roof top equipment.
- Extreme High Tolerance to chemical exposure
- Maintains its thickness for a lifetime.
- Available in Extreme Tough Membrane
- As long a the system is maintained properly by a Certified applicator throughout the course of its life this system can last 50 + years
Cons of using KEE Roofing
- Not ideal for high foot traffic roofs
- Not ideal for Buildings 200’+ in elevation
- Slippery when wet
- For dead level systems Algae will grow in areas of water ponding
Warranty Availability
- KEE Roofing – 10, 15-, 20-, 25-, and 30-year Warranties currently available for this system (25-30 year require upgrade in membrane thickness)
- No Dollar Limit Warranty, Workmanship Warranties, Material and Labor Warranties available
Approved direct substrate applications
- Concrete
- Gypsum
- Gypsum Coverboards
- polyisocyanurate insulation
- Modified Inter-ply membranes only.
KEE Membrane can be Fully adhered directly to the substrates noted above (All structural substrates acceptable)
- EPS
- polyisocyanurate insulation
- Gypsum Coverboards
- Class A Fire barrier
- Over approved existing roofing substrates
KEE Membrane can be Mechanically attached and or Induction welding to the substrates noted above(Building structure Must be Steel, and or wood for this option)
Sly Ply - KEE Roofing
More Specifications
KEE Roofing Colors
- Off White & Bright White are the standard colors available.
- All other standard colors available with min orders of 50,000 SF
- Off white, White, and grey are the only colors that carry an SRI Value of 72+
KEE Durability & Wind Resistance
- KEE Roofing is a Durable roofing system for roofs with minimal traffic and average penetrations, Walk Pad is recommended around all serviceable roof top units.
- KEE carries 55 MPH wind exclusions and is eligible for Wind riders of up to 125 MPH.
Manufacturer Brochure Hyper-Links

Single Ply
EPDM Roofing
Carries an average solar reflective index of 72
Single Ply Types
- TPO
- PVC
- KEE
- EPDM
EPDM Roofing Attachment Methods
- Mechanical Attachment
- Fully adhered.
Pros of using EPDM Roofing
- One of the most Cost-effective Commercial Roofing systems currently available on the market
- Carries an average solar reflective index of 72, meaning this system reflects UV rays which in essence keeps the surface of the roof cool which makes the R Value of your roofing system more efficient which creates cost savings on electricity.
- Most recommended and efficient for large warehouses and or Cold storage spaces
- The warranty does not require substrate slope to achieve a premium 20-year NDL warranty.
- Available in Reinforced and Non-Reinforced Systems
- Very user friendly, Minimal workmanship error
- Average chemical resistance exposure
- As long a the system is maintained properly by a Certified applicator throughout the course of its life this system can last 20-40 years
Cons of using EPDM Roofing
- This product is rarely installed in the State of Florida and is most Popular in other areas of the country.
- Not ideal for high foot traffic roofs
- Not ideal for Buildings 200’+ in elevation
- Not Ideal for buildings with Cooling Towers as the chemicals are much more abrasive and can cause premature failures.
- For dead level systems Algae will grow in areas of water ponding
Warranty Availability
- TPO Roofing – 10, 15-, 20-, 25-, and 30-year Warranties currently available for this system (25-30 year require upgrade in membrane thickness)
- No Dollar Limit Warranty, Workmanship Warranties, Material and Labor Warranties available
Approved direct substrate applications
- Concrete
- Gypsum
- Gypsum Coverboards
- polyisocyanurate insulation
- Modified Inter-ply membranes
EPDM Membrane can be Fully adhered directly to the substrates noted above
- EPS
- polyisocyanurate insulation
- Gypsum Coverboards
- Class A Fire barrier
- Over approved existing roofing substrates
EPDM Membrane can be Mechanically attached and or Induction welding to the substrates noted above
Single Ply
EPDM Roofing
Carries an average solar reflective index of 72
Single Ply Types
- TPO
- PVC
- KEE
- EPDM
EPDM Roofing Attachment Methods
- Mechanical Attachment
- Fully adhered.
Pros of using EPDM Roofing
- One of the most Cost-effective Commercial Roofing systems currently available on the market
- Carries an average solar reflective index of 72, meaning this system reflects UV rays which in essence keeps the surface of the roof cool which makes the R Value of your roofing system more efficient which creates cost savings on electricity.
- Most recommended and efficient for large warehouses and or Cold storage spaces
- The warranty does not require substrate slope to achieve a premium 20-year NDL warranty.
- Available in Reinforced and Non-Reinforced Systems
- Very user friendly, Minimal workmanship error
- Average chemical resistance exposure
- As long a the system is maintained properly by a Certified applicator throughout the course of its life this system can last 20-40 years
Cons of using EPDM Roofing
- This product is rarely installed in the State of Florida and is most Popular in other areas of the country.
- Not ideal for high foot traffic roofs
- Not ideal for Buildings 200’+ in elevation
- Not Ideal for buildings with Cooling Towers as the chemicals are much more abrasive and can cause premature failures.
- For dead level systems Algae will grow in areas of water ponding
Warranty Availability
- TPO Roofing – 10, 15-, 20-, 25-, and 30-year Warranties currently available for this system (25-30 year require upgrade in membrane thickness)
- No Dollar Limit Warranty, Workmanship Warranties, Material and Labor Warranties available
Approved direct substrate applications
- Concrete
- Gypsum
- Gypsum Coverboards
- polyisocyanurate insulation
- Modified Inter-ply membranes
EPDM Membrane can be Fully adhered directly to the substrates noted above
- EPS
- polyisocyanurate insulation
- Gypsum Coverboards
- Class A Fire barrier
- Over approved existing roofing substrates
EPDM Membrane can be Mechanically attached and or Induction welding to the substrates noted above
Sly Ply - EPDM Roofing
More Specifications
EPDM Roofing Colors
- Only available in White or Black
- White is the only option that carries an SRI Value of 72+
EPDM Durability & Wind Resistance
- EPDM Roofing is a Durable roofing system for roofs with minimal traffic, Walk Pad is recommended around all serviceable roof top units.
- EPDM carries 55 MPH wind exclusions and is eligible for Wind riders of up to 125 MPH.
Manufacturer Brochure Hyper-Links
- https://www.carlislesyntec.com/Document-Viewer/top-10-reasons-to-choose-sure-white-epdm/PC8xOSNg10GeHeKTSLO-iA
- https://www.jm.com/content/dam/jm/global/en/commercial-roofing/brochures/RS-7301%20Final%20General%20Roofing%20Catalog.pdf
- https://www.buildsite.com/pdf/carlislesyntec/Sure-Flex-KEE-HP-Membrane-Summary-Brochure-1433832.pdf